boolean

DIN rail mounted version of the EASYswitch

What is the EASYdin

The ability to switch 240 volt or 110 volt mains power safely and simply is achieved by this locally made, DIN rail compliant device. The EASYdin  provides on – off control of the mains via external contact closure, 5 volt, 12 volt or 24 volt signal.

Rugged relay capacity of 1 pole 16A, 1 form C (CO) contact for inrush peak currents up to 30A max. for 4 seconds.

Requiring only a volts free contact closure to switch the full mains supply, it can be operated over kilometres of basic telephone wire by a  switch, relay contact or open collector transistor as used in controllers, A/V and Security equipment.

With user selectable mains supply (240V or 110V), and selectable
output supply of normally open (NO) or normally
closed (NC), designers and installers need stock only one device for
universal power control.

Application Notes

Where is the EASYdin used

Audio, Home Theatre, Lighting, Security and Automation equipment all benefit from the remote switching provided by the EASYdin

Legally and safely switch mains power. 1000’s are in use throughout Australia by the electrical and electronic industry.

How is the EASYdin used in NO operation

01. Connect incoming Line to terminal LINE IN L, and Neutral to a NEUTRAL COMMON N terminal..

02. Connect the required LINE OUT NC or NO and unused NEUTRAL COMMON N to the controlled load..

03. Attach signal wire or similar to the control terminals.

04. Run the control wire to the remote switch mechanism.

05. Switch on source of 24O volt power.

06. GREEN LED indicates power on and the load de-energised.

07. Short remote control contacts terminals of the EASYdin.

08. RED LED indicates active out and the load energised.

EASYdin Specifications

  • Compliant to DIN rail mounting system
  • Controller size 98mm (3.85in ) x 53mm (2.09in ) x 58mm (2.28in )
  • Weight approx. 300g. packaged
  • Contact electrical life 2 x 105operations @ 240 VAC 16A resistive load, derate accordingly for inductive and capacitive loads.
  • Contact capacity: Inrush peak current up to 30A maximum for 4 seconds.
  • Voltage free control line contacts require switching capability of 24VDC open circuit and 3mA closed. Maximum control line resistance 10K ohm.
  • Complies with: AS/NZS 3197:2005, C-tick, ROHS and CE certification.
  • We Design and Manufacture Professional Electronic Equipment
  • Trusted supplier to Government, Industry and Consumers for 40 years